SIZE A Frame

SIZE A Frame

ID Name Remarks
① Nixie tube display 5 digit 7 segment LED digital tube
② Key-type operator Operation mode, with settings of functions, parameters and monitoring
③ CHARGE(Bus voltage indicator) Power indicator light
④ L1C, L2C(Control power input terminal) Power supply of control loop, connected to single-phase power supply (AC200~240V,50/60Hz power supply)
L1, L2, L3(Main power input terminal) Power supply of main loop, connected to single/3-phase power supply (AC200~240V,50/60Hz power supply)
⑤ P/B(Regenerative resistor connection terminal) P/B are connected to external regenerative resistors
P/N(common DC bus terminal) Common DC bus for multiple servos
U/V/W(servo motor connection terminal) Servo drive output, connected to motor power connector (U/V/W)
⑥ CN1(Mini USB) Mini USB connector, connected to PC
⑦ CN2(Connector for safety function) STO connector, only 'P/E/F' models support this option
⑧ CN3/CN4(Communication terminal) EtherCAT high-speed communication port
⑨ CN5(I/O Connector) I/O signals are connected to programmable controller (PLC) or control I/O with connectors
⑩ CN6(Encoder connector) Encoder connector, connected to the encoder on servo motor
⑪ CN7(Fully Closed Loop Encoder Connector) Fully closed loop connector, connected to th external second encoder. This function is supported by '-*C/*G' models
⑫ CN8(Reserved) Reserved interface
⑬ Ground screw Connect to earth wires of power supply and motors