Technical Specifications
| Model | SRE5012 |
| Technical Specifications | |
| High-speed counting channel | 2-channel (A, B, C) single-ended input maximum 200KHZ (supports rated voltage 5VDC and 24VDC);Differential maximum 4MHZ, rated voltage 5VDC |
| Bus 5VDC current consumption | 200mA |
| High-speed counter input characteristics | Single-ended (rated 24V, maximum 200kHz), differential (5V, maximum 4MHz) |
| Latch input characteristics | Single-ended input, 24V |
| Gated signal output | 2DO, NPN type |
| Distributed clock | Supported |
| High-speed counting mode |
1. Single-ended count: The Phase A input is used for counting pulses, while the Phase B input defines the counting direction: count up when B is high level, count down when B is low level. 2. Differential count: Phase A and B pulses are orthogonal. Counts up when Phase A leads Phase B by 90 degrees, and counts down when Phase B leads Phase A. 3. Master enables the current count value setting function. When the counter is set as TRUE, the current count value will be set as the preset value. 4. Master enables the latching function, which can be set on the rising edge of Phase C, the rising edge or the falling edge of the LATCH input to latch the current count value. |
| Isolation | |
| Between channels and buses | Existent |
| Display indicator | Power supply green LED display |
| System power diagnosis and warning | Supported |
| Environmental conditions | Operating temperature: -20~60℃; relative humidity: 5%~90% (non-condensing) |
| Storage temperature | -40~60 °C |
| Dimensions (L × W × H) | 30×80×100(mm) |