ID |
Name |
Remarks |
① |
Nixie tube display |
5 digit 7 segment LED digital tube |
② |
Key-type operator |
Operation mode, with settings of functions, parameters and monitoring |
③ |
CHARGE(Bus voltage indicator) |
Power indicator light |
④ |
L1C, L2C(Control power input terminal) |
Control power supply of loop, connect to single phase power supply(depending on model 200~240VAC or 380~440VAC, 50/60Hz power supply) |
R/S/T(Main power input terminal) |
Main loop power supply, connect to single/three phase power supply(depending on model 200~240VAC or 380~440VAC, 50/60Hz power supply) |
P, RB, B(Regenerative resistor connection terminal) |
Use external regenerative resistor(remove the shorting cap of P and RB; Connect it to both ends of P and B) |
P/N1/N2(Common DC bus terminals) |
Do not remove the shorting cap between N1 and N2. Connect it between P and N1 for common DC bus of multiple servos |
U/V/W(servo motor connection terminal) |
Servo drive output, connected to motor power connector (U/V/W) |
⑤ |
CN1(Mini USB) |
Mini USB port, connected to PC |
⑥ |
CN2(Connector for safety function) |
STO connector, only 'P/E/F' models support this option |
⑦ |
CN3/CN4(Communication terminal) |
EtherCAT high-speed communication port |
⑧ |
CN5(I/O Connector) |
I/O signals are connected to programmable controller (PLC) or control I/O with connectors |
⑨ |
CN6(Encoder connector) |
Encoder connector, connected to the encoder on servo motor |
⑩ |
CN7(Fully Closed Loop Encoder Connector) |
Fully closed loop connector, connected to th external second encoder. This function is supported by '-*C/*G' models |
⑪ |
Ground screw |
Connect to earth wires of power supply and motors |