ID |
Name |
Remarks |
① |
Nixie tube display |
5 digit 7 segment LED digital tube |
② |
Key-type operator |
Operation mode, with settings of functions, parameters andmonitoring |
③ |
CHARGE(Bus voltage indicator) |
Power indicator light |
④ |
L1C, L2C(Control power inputterminal) |
Power supply of control loop, connected to single-phase powersupply (AC200~240V,50/60Hz power supply) |
L1, L2, L3(Main power inputterminal) |
Power supply of main loop, connected to single/3-phase powersupply (AC200~240V,50/60Hz power supply) |
⑤ |
P/B(Regenerative resistorconnection terminal) |
P/B are connected to external regenerative resistors |
P/N(common DC bus terminal) |
Common DC bus for multiple servos |
U/V/W(servo motor connectionterminal) |
Servo drive output, connected to motor power connector(U/V/W) |
⑥ |
CN1(Mini USB) |
Mini USB connector, connected to PC |
⑦ |
CN2(Connector for safety function) |
STO connector, only 'P/E/F' models support this option |
⑧ |
CN3(I/O Connector) |
I/O signals are connected to programmable controller (PLC) orcontrol I/O with connectors |
⑨ |
CN4(Encoder connector) |
Encoder connector, connected to the encoder on servo motor |
⑩ |
CN5(Fully Closed Loop EncoderConnector) |
Fully closed loop connector, connected to th external secondencoder. This function is supported by '-*C/*G' models |
⑪ |
CN6(Reserved) |
Reserved interface |
⑫ |
Ground screw |
Connect to earth wires of power supply and motors |