SIZE A Frame

SIZE A Frame

ID Name Remarks
Nixie tube display 5 digit 7 segment LED digital tube
Key-type operator Operation mode, with settings of functions, parameters andmonitoring
CHARGE(Bus voltage indicator) Power indicator light
L1C, L2C(Control power inputterminal) Power supply of control loop, connected to single-phase powersupply (AC200~240V,50/60Hz power supply)
L1, L2, L3(Main power inputterminal) Power supply of main loop, connected to single/3-phase powersupply (AC200~240V,50/60Hz power supply)
P/B(Regenerative resistorconnection terminal) P/B are connected to external regenerative resistors
P/N(common DC bus terminal) Common DC bus for multiple servos
U/V/W(servo motor connectionterminal) Servo drive output, connected to motor power connector(U/V/W)
CN1(Mini USB) Mini USB connector, connected to PC
CN2(Connector for safety function) STO connector, only 'P/E/F' models support this option
CN3(I/O Connector) I/O signals are connected to programmable controller (PLC) orcontrol I/O with connectors
CN4(Encoder connector) Encoder connector, connected to the encoder on servo motor
CN5(Fully Closed Loop EncoderConnector) Fully closed loop connector, connected to th external secondencoder. This function is supported by '-*C/*G' models
CN6(Reserved) Reserved interface
Ground screw Connect to earth wires of power supply and motors