Menu

Wall-assembled

Assembly Method

The wall-assembled Industrial Intelligent Computer is designed for space-constrained applications requiring permanent mounting, such as control cabinets, equipment enclosures, or vertical surfaces. Standard assembly procedure is as follows:


Equipment and Assembly Environment Inspection

Prior to assembly:

  • Confirm location provides adequate ventilation clearance (>10cm from walls/obstructions)
  • Verify mounting surface structural integrity to withstand 17kg device weight with 5G vibration tolerance
  • Maintain ≥5-10cm service clearance for thermal management and maintenance access

Bracket Assembly

  1. Select Mounting Hardware:
    Use VESA 75/100 compliant bracket or proprietary mount kit matching IP54-rated enclosure
  2. Mark Drilling Coordinates:
    Transfer device's M4 mounting hole pattern to surface using template
  3. Drill and Secure Anchors:
    For concrete/steel surfaces:
    • Drill Ø6mm holes at markings
    • Install M4 expansion anchors with 0.8Nm torque

Device Assembly

  1. Bracket-to-Surface Assembly:
    Secure bracket using M4×12mm stainless steel screws (8.8 grade)
  2. Device-to-Bracket Assembly:
    Engage device with bracket, apply 1.2Nm torque to four corner fasteners

Cable Integration

  1. Port Connection Sequence:
    ① Power → ② Ethernet → ③ I/O → ④ Display cables
  2. Strain Relief Implementation:
    • Maintain ≥25mm bend radius on all cables
    • Install cable clamps within 100mm of connectors
    • Secure bundles with UV-resistant nylon ties (max 150mm spacing)

Post-Assembly Verification:

  • Confirm <0.5mm bracket deflection with 20N force
  • Validate all connectors achieve IP54 seal rating
  • Perform 48h thermal cycle test (-10℃ to 50℃)
Last modified: 2025-06-16