Product Model |
SX5232-1111 |
SX5232-1121 |
SX5232-2112 |
SX5232-2122 |
Main system |
CPU |
Intel® Processor N series |
Memory (G) |
8GB |
16GB |
Storage |
Default 128G, expandable to 1T |
Default 256G, expandable to 1T |
EtherCAT slaves |
32 EtherCAT slaves (servo axes or IO) |
Hardware interface |
Network port |
4 |
USB |
2 |
Serial port |
1*RS232/RS422/RS485 |
CAN |
1 |
HDMI |
1 |
Software interface |
Programming language |
Support IEC61131-3 (LD/ST/CFC/SFC) |
Program download |
Support binary object code and user engineering (active, passive) downloads |
Program upload |
Support |
Program encryption |
Support user engineering, POU and target file encryption |
Controller encryption |
Support locking/unlocking of the controller |
Power-down hold |
Support |
Automatically add libraries |
Support |
Online system upgrade |
Support |
Desktop operating system |
Ubuntu |
Real time clock (hold time) |
Duration (15 days), accuracy ±60 seconds/month |
Module power supply |
Operating voltage (VDC) |
20.4~28.8(-15%~+20%) |
Rated voltage (VDC) |
24 |
Power consumption Pmax (W) |
≤45 |
Environment |
Operating temperature (°C) |
-20~+60 |
Storage temperature (°C) |
-40~+80 |
Humidity |
5~95%, without condensation |
Certification |
N/A |
Input/Output Specifications
|
Input Points |
8*DI |
Input Type |
Supports PNP/NPN (distinguished by wiring) |
Rated value |
24V DC |
0 Signal Voltage |
<5V |
1 Signal Voltage |
>15V |
Permissible Static Current |
1mA |
Insulation Test Voltage |
500V DC |
Output Points |
4*DO |
Output Type |
PNP |
NPN |
PNP |
NPN |
Output Short-Circuit Protection |
Equipped, electronic |
Maximum Light Load |
5W |
Output Current “1” |
0.5A |
Leakage Current |
<1mA |
Adaptive I/O Points |
Supports 4*adaptive I/O (DI01-DI04) |
Adaptive I/O Type |
PNP |
NPN |
PNP |
NPN |
Adaptive I/O Configuration Description |
DI01-DI04 can be independently configured as input or output, distinguished by input connection method (connected to M/L+) and output status indication (LED). |
Backplane Bus Current Consumption (5V) |
180mA |
Local Expansion |
Supports SRE series local expansion modules. For more than 8 modules, a separate power relay module is required. |