SIZE B Frame

SIZE B Frame

 

ID Name Remarks
Nixie tube display 5 digit 7 segment LED digital tube
Key-type operator Operation mode, with settings of functions, parameters andmonitoring
CHARGE(Bus voltage indicator) Power indicator light
L1C, L2C(Control power inputterminal) Power supply of control loop, connected to single-phasepower supply (AC200~240V,50/60Hz power supply)
L1, L2, L3(Main power inputterminal) Power supply of main loop, connected to single/3-phasepower supply (AC200~240V,50/60Hz power supply)
P, RB, B(Regenerative resistorconnection terminal) Use external regenerative resistor(remove the shorting cap ofP and RB; Connect it to both ends of P and B)
P/N(common DC bus terminal) Common DC bus for multiple servos
U/V/W(servo motor connectionterminal) Servo drive output, connected to motor power connector(U/V/W)
CN1(Mini USB) Mini USB connector, connected to PC
CN2(Connector for safety function) STO connector, only 'P/E/F' models support this option
CN3(I/O Connector) I/O signals are connected to programmable controller (PLC)or control I/O with connectors
CN4(Encoder connector) Encoder connector, connected to the encoder on servomotor
CN5(Fully Closed Loop EncoderConnector) Fully closed loop connector, connected to th external secondencoder. This function is supported by '-*C/*G' models
CN6(Reserved) Reserved interface
Ground screw Connect to earth wires of power supply and motors