SIZE B Frame
ID | Name | Remarks |
① | Nixie tube display | 5 digit 7 segment LED digital tube |
② | Key-type operator | Operation mode, with settings of functions, parameters andmonitoring |
③ | CHARGE(Bus voltage indicator) | Power indicator light |
④ | L1C, L2C(Control power inputterminal) | Power supply of control loop, connected to single-phasepower supply (AC200~240V,50/60Hz power supply) |
L1, L2, L3(Main power inputterminal) | Power supply of main loop, connected to single/3-phasepower supply (AC200~240V,50/60Hz power supply) | |
⑤ | P, RB, B(Regenerative resistorconnection terminal) | Use external regenerative resistor(remove the shorting cap ofP and RB; Connect it to both ends of P and B) |
P/N(common DC bus terminal) | Common DC bus for multiple servos | |
U/V/W(servo motor connectionterminal) | Servo drive output, connected to motor power connector(U/V/W) | |
⑥ | CN1(Mini USB) | Mini USB connector, connected to PC |
⑦ | CN2(Connector for safety function) | STO connector, only 'P/E/F' models support this option |
⑧ | CN3(I/O Connector) | I/O signals are connected to programmable controller (PLC)or control I/O with connectors |
⑨ | CN4(Encoder connector) | Encoder connector, connected to the encoder on servomotor |
⑩ | CN5(Fully Closed Loop EncoderConnector) | Fully closed loop connector, connected to th external secondencoder. This function is supported by '-*C/*G' models |
⑪ | CN6(Reserved) | Reserved interface |
⑫ | Ground screw | Connect to earth wires of power supply and motors |