Indicator Instructions
| State | Explain | |
| green light | Booon slow flash 5 times (once 1s) -> Chang bright (2s) -> flash 7 times (once 500ms) -> flicker once-> out | Diagnostic instrument was connected to the gateway successfully (V 3207-zg)(Sensor first connected to this gateway) |
| Booon slow flash 5 times (1s once) -> Chang bright (2s) -> flicker once-> out | Diagnostic instrument was connected to the gateway successfully (V 3207-zg)(Sensors were previously connected to this gateway) | |
| green light | Booon slow flash 5 times (1s once) -> Chang bright (2s) -> flash 7 times (500ms once) -> out | The Diagnostics machine has failed to connect to the gateway(ZigBee) |
| green light | Booon slow flash 5 times (1s once) -> Chang bright (20s, sensor network process) -> flicker once-> out | The diagnostic instrument was successfully connected to the cloud platform(PDA) |
| green light | Booon slow flash 5 times (1s once) -> Chang bright (20s, sensor injection process) -> out | The diagnostic failed to connect to the cloud platform(PDA) |
Installation Location
The intelligent wireless diagnostic instrument is generally arranged on the main bearing or main bearing seat of the pump equipment, and the machine cover, cover plate and other parts are not suitable for measuring points.
The corresponding installation position of each type is shown in the figure.
Suspension arm centrifugal pum
Quantity: 1~2
It must be installed in the vertical direction (V direction shown in the figure)
Near the drive end bearing position
If in case, install to both ends of the bearing case

Support pump at both ends
Quantity: 2
Installation location is vertical (V direction shown in the figure)
One bearing position at each end

Vertical pipe pump
Quantity: 1
Pump type with bearing body structure is mounted to the shaft
Bearing position (Y direction shown in Figure 1)

Low voltage motor
Quantity: 2
Installation location is vertical (V direction shown in the figure)
One bearing position at each end
Note: Dual terminals adopt the "main + secondary" working mode.
Optional 1 time is installed on the drive end
Installation method: stud installation

High voltage motor
Quantity: 2
Installation location is horizontal (H direction shown in the figure)
One bearing position at each end
Note: Dual terminals adopt the "main + secondary" working mode.
It is recommended to be installed in "main + auxiliary" working mode.

High voltage motor
Quantity: 2
Installation location is vertical (V direction shown in the figure)
One bearing position at each end
Note: Dual terminals adopt the "main + secondary" working mode.
It is recommended to be installed in "main + auxiliary" working mode.

High pressure centrifugal fan
Quantity: 1
Installation location is vertical (V direction shown in the figure)
Near the drive end bearing position

Induced draft fan
Quantity: 2
Installation location is vertical (V direction shown in the figure)
One bearing position at each end of the bearing seat
Note: Dual terminals adopt the "main + secondary" working mode.

centrifugal blower
Quantity: 2
Installation location is vertical (V direction shown in the figure)
One bearing position at each end of the bearing seat
Note: Dual terminals adopt the "main + secondary" working mode.

Installation Method
Magnetic suction installation
Installation interface requirements: magnetic suction plane ø 23mm
Installation accessories: ø20X8mm magnetic seat * 1

Adhesive installation
Installation interface requirements: adhesive plane ø 23mm
Installation accessories: special metal glue * 1

Note:
- In order to ensure the best installation stability and temperature monitoring accuracy, it is recommended to use stud installation.
- Strong magnets will demagnefy for a long time and high temperature. When the surface temperature of the equipment is higher than 55°C, it is recommended to use stud or adhesive installation.
Installation Steps
Bolt installation
Screw the product clockwise into the stud, to ensure that the sensor Z axis

Magnetic suction installation
1.Tighten the magnetic seat clockwise to the product

2.Adsorb the product to the equipment installation point to ensure that the sensor's Z-axis is perpendicular to the equipment axis and the X-axis is parallel to the equipment axis.

Adhesive installation
1.Tighten the magnetic seat clockwise to the product

2.Assemble the special metal rubber gun and press the booster

3.Apply the glue evenly to the bottom surface of the magnetic base

4.Attach the sensor to the installation point of the equipment to ensure that the sensor Z axis direction is perpendicular to the equipment axis, and the X axis direction is parallel to the equipment axis

Installation direction
The height direction of intelligent wireless diagnostic instrument (such as the Z axis direction on the right) needs with the pump.
The equipment axis is vertical, and the Y-axis direction is parallel to the axis.
X: Horizontal Y: Axial Z: vertical (spindle)

Note:
Do not remove the host shell and base by yourself, otherwise it may lead to product failure.