CN7 Full closed-loop encoder

Definition of fully closed-loop encoder interface

Fully Closed loop encoder Connector (CN7) Module name Signal name No. Wiring method Functions
 IEEE 1394 10P Fully closed-loop encoder 5V 1 Twisted pair Encoder power supply
GND 2
SEC_A+ 3 Twisted pair Second encoder input interface
SEC_A- 4
SEC_B+ 5 Twisted pair
SEC_B- 6
SEC_Z+ 7 Twisted pair
SEC_Z- 8
9  
MTR_TEMP 10   Input of motor temperature sensor
Shell Connect the cable shielding layer Shielded

This port is used for connection between drive and motor encoder. During use, distance between the cable and main circuit wire should be 30cm;

  • Please use shielded twisted pair cable for encoders;
  • Input of fully closed-loop encoder is differential input, and its Max. input frequency and Min. pulse width are shown in the table below:
Pulse method Max. frequency (pps) Min. pulse width (μs)
Differential input 4M 0.125


CN7 Input of motor temperature sensor

Support PT/NTC/switch types of motor temperature sensors. Please ensure that function codes P00.05/P08.31/P08.33/P08.34 are set properly.