Assembly Site
| Please install in an electric control cabinet free from sunshine and rain |
| Do not use this product in corrosive environment with hydrogen sulfide, chlorine gas, ammonia, sulfur, chlorinated gas, acid, alkali, salt |
| Do not use this product in the presence of flammable gases or near the combustible |
| Do not install in an environment with high temperature, humidity, dust, or metal dust |
| Vibration-free site |
| Installation site contamination level: PD2 |
Environmental Conditions
Environment conditions of drive installation
| Item |
Description |
| Operating ambient temperature |
0 ~ +40 ℃ |
| Ambient humidity |
Less than 90%RH (no condensation) |
| Storage temperature |
-20~70℃(non-freezing) |
| Storage humidity |
Less than 90%RH (no condensation) |
| Vibration |
Below 4.9m/s2 |
| Impulse |
Below 19.6m/s2 |
| Class of protection |
IP20 Note: Except Terminal (IP00) |
| Altitude |
The highest altitude is 5,000m. Derating is unnecessary for 1,000m or below; Derating rate is 1% per 100m rise above 1,000m. Please contact the manufacturer in case of altitudes over 2,000m. |