Menu

Technical Specifications

Technical Specifications

Product Model SRL3404
Technical specifications
Power supply voltage 18V DC~28V DC
Number of input channels 4
Acquisition type Voltage/Current
Measuring range
Voltage (Unipolar) 0~10V、-10V~0V
Voltage (Bipolar) -10V-10V
Current 0~20mA、4~20mA
Data word
Unipolar 0~7812500
Bipolar -7812500~7812500
Resolution 24-Bit
Analog accuracy 0.01% (At 23°C, full scale)
Oversampling factor n = 1...64
Sampling frequency 10ksps(1000us)
Limit frequency of input filtering 3KHz
Internal impedance >500KΩ(30V); >4MΩ (Others) 150Ω (Current)
Isolation
Between channels and buses Existent
Display indicator Power supply green LED display
Distributed clock Supported
System power diagnosis and warning Supported
Environmental conditions
Environmental conditions Operating temperature: -20~60°C, relative humidity: 5%~90% (non-condensing)
Vibration/shock resistance Compliant with EN 60068-2-6/EN 60068-2-27 Standards
EMI/EMR resistance Compliant with EN 61000-6-2/EN 61000-6-4 Standards
Dimensions (L × W × H) 24×100×64 (mm)
Last modified: 2025-12-23